1 5/16" Form Deck Deep Verco Deck Rendering

1 5/16″ FORM DECK

1 5/16 Form Deck or non-composite pan decking is a shallow economical steel form used for concrete slabs. If you need help with a speciation or design intent, give us a call.

(509) 508-4010

    Quantity
    Length
    Gauge
    Finish
    Custom Length:
    Specified Deck Type {Sidelap Connection}

    Proudly Serving Nationwide!

    Description

    1 5/16" deep form deck is a shallow steel deck used as a permanent form for concrete slabs, with a depth of 1 5/16". It is commonly used in construction for floors with slabs approximately 3.5"-5" deep. Unlike composite decks, this pan deck does not have embossments and is not designed to bond with the concrete.

    1 5/16" Form Deck Deep Verco Dimensions

    Joist & Deck Experts:

    Tombari Joist & Deck is the most reliable supplier - we provide accurate bids and expert project execution for joist and deck needs. Our team thoroughly reviews every detail to deliver competitive pricing and efficient project coordination. We are ready and able to support you throughout every phase to ensure your project stays on budget and on schedule.

    1 5/16" Gauge(s)

    26

    GAUGE

    24

    GAUGE

    22

    GAUGE

    20

    GAUGE

    1 5/16" Deck Sidelap Attachment(s)

    Metal deck sidelap attachments are the fasteners that connect adjacent sheets of steel deck at their overlapping edges, commonly known as side laps. The EOR or design team, is responsible for specifying the type and spacing of sidelap attachments. This specification is crucial as sidelap attachments play a vital role in the structural integrity of the metal deck, the diaphragm to resist lateral forces from wind or seismic activity.

    Standard Nesting or Lapping Sidelap

    NESTABLE

    Nestable deck is also designed generally for screw side lap style of B decking. Note the nestable side lap has a lower shear value and must be determined by the EOR.

    Form Deck Finishes:

    The metal deck finish is the coating on the steel deck surface, which will vary depending on the application. The EOR or design professional is responsible for specifying the finish of metal deck on a job by job basis.

    • Roof deck finishes are most commonly shop coated, G-60 and G-90 varieties.
    • Composite deck finishes typically uses galvanized steel to promote a bond with the concrete. Note composite decks cannot have a painted top surface as it creates potential bonding issues between the concrete and the metal deck.
    • Form deck finishes are most commonly to be galvanized, or galvanized top with a painted bottom.

    PRIME PAINT

    A1008 Prime Painted Steel Decking: A temporary, provisional primer (gray or white) applied to cold rolled steel, offering protection before field-applied finishes and most often used for roof deck.

    G-30

    A653 Galvanized G-60 zinc coated steel is the standard in the deck industry. G30 has approximately 0.3 ounces of zinc per square foot. Generally for warehouse or large sq ft.

    G-60

    A653 Galvanized G-60 zinc coated steel is the standard in the deck industry. G60 has approximately 0.6 ounces of zinc per square foot.

    G-90

    A653 Galvanized G-90 is typically specified for exterior applications or more corrosive enviromentys with approximately .9 ounces of zinc per square foot.

    FINISH PAINT

    A653 Finish Paint: Specialty finishes (Epoxy or Tenmic) can be applied either pre- or post-manufacturing, most common in highly corrosive environments rather than architectural coats.

    GALV + PAINT

    A653 Galvanized + Paint: A combination of galvanization and primer, ideal for projects requiring both corrosion resistance and the ability to apply additional field paints.

    PHOS PAINT

    A1008 Phosphatized Painted: Steel decking with a phosphatized black surface that develops slight rust before concrete is poured, with the underside painted for additional protection.

    Form Deck Options:

    Steel Decking and special variations such as acoustical, cellular, or vented metal decking are generally specified by the EOR or design professional to meet requirements on a project. The choice of a variation is determined during the design phase and typically requires a special manufacturing process, or coil. Note these variations are often indicated structural design drawings or specifications.

    Metal Deck Hangar Tab Vents

    VENTED

    Slotted or vented metal roof deck offers factory-punched vent tabs to ensure effective airflow to aid in curing concrete or to prevent moisture from being trapped in the slab during slab waterproofing applications. Consider that when venting metal deck, minor leakage can occur during concrete placement. The row configurations vary by profile; contact us for more details.


    Certifications

    The specific certifications required for a project are typically outlined in project documents, including specifications, drawings, and contracts. There are many reasons why metal deck certifications are important, we are ready to help you through the submittal process for any and all certifications with proper documentation.

    SDI Members

    The SDI (Steel Deck Institute) provides uniform industry standards for the engineering, design, manufacturing, and field application of steel deck. We only supply materials SDI Approved to promote safe and effective construction practices. Learn more about why the SDI is important at SDI.org.

    Domestic Steel

    We can supply the required steel MTRs or mill certificates as required for evidence of domestic steel. We are able to meet both Buy America and Buy American requirements. Be sure to notate this with our sales team at the time of order.

    Factory Mutual (FM)

    FM Global is a commercial property insurance company that also provides loss prevention engineering services and sets property loss prevention standards, including standards for building materials. FM Approved metal deck is designed to meet these specific standards for fire resistance and structural performance. Our products meet meet Factory Mutual (FM) Approvals as: FM Global's RoofNav program, may be searched using "steel deck". Note that specific assemblies within RoofNav do not list specific steel decks so as not to unnecessarily restrict what can be used. For an expanded list of allowable spans based upon FM Standard 4451 please contact us.

    UL Approved

    Verco deck is UL approved. UL (Underwriters Laboratories) approved metal deck refers to steel products that have been tested and certified by UL to meet specific fire resistance standards. For projects that require spray-on fireproofing, it's essential to specify paint finishes that are compatible with the applicable fire-rated assembly, as not all paints are approved for use in such assemblies. Search for approved UL Assemblies.

    IAPMO Reports

    Certified with IAPMO Reports. This code reports play an important role facilitating product evaluation processes and provides a service by issuing an informed third-party opinion that a new or alternative structural product meets the intent of the codes, which is essential to the building industry and the public's wellbeing. Contact us to obtain the current IAPMO ES Evaluation Report for your project.

    LEED Compliant

    Metal decks can contribute to LEED (Leadership in Energy and Environmental Design) certification for a building by supporting the construction of energy-efficient and resource-conserving buildings. LEED certified metal deck is metal deck that is manufactured with recycled steel and/or manufactured within 500 miles of the job site. Discuss with us how we can help ensure your metal deck is qualified for LEED certification.

    Los Angeles Research Report (LARR)

    The Los Angeles Department of Building and Safety (LADBS) offers two types of building material and product approvals: General Approval Also known as a Research Report (LARR), this approval is for mass-produced products that can be used on any project site. An evaluation report from an approved product certification agency can demonstrate that a material or product meets the code requirements. The report must be based on the model codes that are current at the time the plan is submitted. Contact us for the current City of Los Angeles Research Report Letter.

    SPECIFICATIONS

    Gauges 26, 24, 24, 22, 20
    Height / Depth 1 5/16 / 1 3/8"
    Industry Names 1.3C, EHD-Dek, UFX, C1.4-32
    Width(s) 36", 32"